HEAT-SAFE HOMES — DATA AND METHODS The CSV uses one row per home and timestamp: site_id,home_id,intervention,timestamp,indoor_c,outdoor_c,humidity_pct,occupied Use non-identifying home and site IDs. The intervention label should stay the same for each home in a file. Use ISO timestamps with a UTC offset, such as 2026-07-15T20:00:00-07:00 or 2026-07-16T03:00:00Z. Use Celsius for temperatures, percentage for relative humidity, and 1 or 0 for occupied; blank means unknown. An identical instant entered twice for the same home is an error, even when the time-zone offsets differ. Blank measurements are missing, never zero. The analysis uses a user-defined window, reference temperature, fixed UTC offset and maximum gap between adjacent readings. It holds each earlier measurement constant until the next eligible measurement and excludes intervals with missing endpoints or gaps longer than the selected maximum. It does not extrapolate before the first or after the final reading. Hours above the reference and degree-hours cover only observed intervals. The reference temperature is an arbitrary analytical parameter, not a health or safety threshold. Coverage and missing counts appear with the results. Night is 22:00–06:00 at the selected fixed offset. Analyze different offsets in separate windows around daylight-saving transitions. An interval is classified as occupied only when both endpoint flags are 1. Relative humidity is time weighted on valid intervals and its coverage is independent of temperature. Relative humidity alone cannot establish mold risk, moisture damage or safety. Two homes must be at the same site to compare them. The tool compares only identical original sensor interval endpoints where both indoor and outdoor readings are present and the outdoor readings differ by no more than 0.5 °C at either endpoint. It shows matching hours and their share of the requested window. Timing and weather matching do not account for differences in the buildings, occupant behavior or other conditions. A descriptive difference does not prove that an intervention caused it. Repeated readings are not independent homes. SELECTED PRIMARY SOURCES Vellingiri and colleagues (2020), sixteen Ahmedabad households: https://www.mahilahousingtrust.org/wp-content/uploads/2022/06/MHT_Combating-Climate-Change%E2%80%90induced-Heat-Stress.pdf Different roof types were compared in short daytime measurements. Homes and weather differ; the study does not establish a universal retrofit effect. Rosado and colleagues (2014), Lawrence Berkeley National Laboratory, two Fresno show homes: https://eta-publications.lbl.gov/sites/default/files/measured_temperature_reductions_and_every_savings_from_a_cool_tile_roof_on_a_central_california_home.pdf Roof material, ventilation and thermal mass differed. An attic-temperature result should not be represented as an occupied-room temperature result. Sharmin and Rahman, 2023 conference proceedings, one Ahmedabad home: https://carbse.org/CATE2023/PaperID_1166_Optimising_energy_efficiency_and_thermal_comfort_measures_for_a_low-income_residential_building_in_Ahmedabad%2C_India.pdf The three-month ventilation comparison was simulated using a model informed by short field measurements; it was not a field-measured intervention effect. This tool processes chosen input in your browser. No field pilot or safety assessment is established by the included synthetic example.